2008 Buildings Bulletins |
|||
Issuance |
Type/ |
Relevant Code Sections |
Purpose |
March 24, 2008 |
Technical / Superseded by: Buildings Bulletin 2011-011 Related to: |
BC 1808.2.3 |
This document addresses the use of helical piles per the 1968 Building Code and the 2008 NYC Building Code. |
June 26, 2008 |
Code Interpretation / Buildings Bulletin 2008-001 Prospectively Rescinded by: |
BC 303.1 |
This document is to clarify that accessory spaces used for assembly purposes with occupant loads of less than 75 are not subject to the 10% per story limits and are treated as the main occupancy for code purposes. |
June 26, 2008 |
Code Interpretation / Buildings Bulletin 2008-002 Prospectively Rescinded by: |
BC 307.1 |
This document is to clarify 1) that Section BC 414 applies to all spaces that contain hazardous materials regardless of quantity of such materials and occupancy classification, and regardless of whether the space is an incidental use area, and 2) that spaces listed on Table 508.2 as incidental use areas are classified as a Group H occupancy if the quantities exceed those found in Tables 307.7(1) and 307.7(2). |
June 26, 2008 |
BC 503.1 |
This document is to clarify that the floor area exemption in Section BC 505.1 for mezzanines applies only to the height and area limitations of Section BC 503.1, and does not serve as an exemption of floor area under the Zoning Resolution. |
|
June 26, 2008 |
Code Interpretation / Buildings Bulletin 2008-004 Prospectively Rescinded by: |
BC 907.2.12.2 |
This document is to clarify the operation of emergency voice/communications systems, including that only live voice announcements by Fire Safety Directors or FDNY are permitted, except as may be provided for in I-1 and I-2 occupancies. |
June 26, 2008 |
Code Interpretation / Buildings Bulletin 2008-005 Prospectively Rescinded by: |
PC412.3 |
This document is to resolve the apparent conflict between the minimum trap sizes of Table PC 709.1 and the minimum drain outlet diameters of Sections PC 412.3, 417.3, and 418.2 with regard to floor drains, sinks and showers. |
June 26, 2008 |
T28 109.3 |
This document is to clarify that the term “Fire Command Station” is interpreted to mean “Fire Command Center”. |
|
August 21, 2008 |
Legal / Superseded by Legal / |
Caretaker's Apartment: ZR 12-10 Driveway/Frontage Space: Egress: Flood Zone Flood Zone Off-street Parking: Party Wall: Plumbing System: Student Dormitory: |
To set forth procedures and requirements for the filing, review, approval and documentation of proposed easement agreements and restrictive declarations. |
October 21, 2008 |
AC 27-292.10 |
This document serves as a reminder of the requirement of accessible service counters in banking institutions where customer service is provided. |
|
October 29, 2008 |
BC 503 (Table) |
This document provides a general guide for the occupancy classification of incidental use areas and accessory occupancies. |
|
November 14, 2008 |
Technical / Prospectively Rescinded by: |
BC 1213.3 |
This document clarifies when a refuse chute may be omitted from a hotel. |
November 21, 2008 |
Technical / Prospectively Rescinded by: |
PC 106.6.1: Exception |
This document clarifies that the exception for providing drainage for impervious surfaces is applicable only where the resulting, final total impervious surfaces on the lot are 1,000 square feet or less. |